> One of the H744 regulators whines

FWIW, none of mine are silent under load. If they're not being loaded (e.g. on 
a test bench, with no dummy load, or if you have all the boards out) they can 
whine excessively due to no minimum load.

> it seems higher than the expected values printed on the meter

Beware cheap test equipment. $client has a few of these Chinese handheld LC/RLC 
meters, they're wildly inaccurate on some parameters, including ESR on large 
electrolytics. We've got a proper Gen-Rad RLC Digibridge in the shop to compare 
against. We couldn't figure out why some of their tuned filter stages were 
failing QC at a much higher rate than expected. They were off-frequency because 
the cheap meters were giving consistently incorrect measurements when trying to 
match capacitors.

That said, it's not like replacing them with new will *hurt* -- it just might 
not fix the whine.