On 9/6/25 01:26, Rob Jarratt wrote:
Thanks Jon. In my case even when the outputs are at 0V, I can see the that the 
output transformer is producing outputs, if that is true would that confirm 
that startup is not the issue here?

Well, maybe.  If it is a steady ~20 KHz on the transformer, the startup circuit is OK.  If it is an intermittent pulsing a few times a second, then the startup is "trying" but the converter is failing to power itself.  (Or the crowbar is killing it.)

Jon


Reply via email to