Rudi Ahlers wrote:
> On Thu, Jul 7, 2011 at 3:22 PM, R - elists <list...@abbacomm.net> wrote:
>> rudi
>>
>> when migrating some rackmount HP servers running Centos4 from hard coded
>> 100
>> meg fdx to auto gigE that we had to
>>
>> 1) remove this from our ifcfg-ethX files
>>
>> ETHTOOL_OPTS="speed 100 duplex full autoneg off"
<snip>
A minor detail - I think you *must* have autoneg set first - it applies
them one after the other, in my experience.

ETHTOOL_OPTS="autoneg off speed 100 duplex full"

         mark