I will tell you of our experience
 
Dell perc controllers with HDD and separate Intel NVMe for journals etc
 
With the Disk first behind the controller with caching enabled and it set as a 
raid0  and the OSDs were  encrypted everything was good.
 
When we upgrade to LVM and still encrypted and still raid0 on the perc - 
everything was fine.... for a while
 
As soon as drives started to fail - it became incredibly difficult to find the 
right drive according to the idrac, the OSD and everything was difficult
Remember not all drives actually fail - some go in to a state that go up and 
down or can cause a lot of noise on the bus of the server taking a whole server 
offline
 
So we reconfigured (all / most OSDs / drive to not use raid0 cache) did notice 
a slight drop in performance
BUT we can now find and address the OS/s hard drives in the idrac 
We also don't have to worry about the battery failing on the perc (hopefully 
anyway)
 
So I would test you config before going into production
I also don't know what info the idrac will give you on the SSD, vs the OS tools
 
Joe
 