On Tuesday, December 16, 2025 at 04:17:19 p.m. EST, Anthony D'Atri 
<[email protected]> wrote:

> PLP is crucial, but there are other factors. If you have a choice, NVMe
> SSDs give a lot more bang for the buck than SATA. The Kingstons
> don't have IIRC stellar performance, but maybe you don't need it to be.

The potentially free render nodes don't have NVMe slots, so buying nodes for 
that would unfortunately would immediately raise the capital budget by quite a 
bit.

...although we do have a smaller number of nodes with 4-6 NVMe slots each. So 
then the question becomes: 8-24 nodes with 1-3 SSDs each, or 4-6 nodes with 4-6 
NVMe drives each?

> Those chassis can even only have their server trays partly populated
> too.  Were you to have 8 chassis, you could make `chassis` your
> CRUSH failure domain, with however many drives per chassis/host.

I did look into that, but unfortunately 4-6 chassis is probably the most I can 
reasonably make the case for.

Andrew

  
_______________________________________________
ceph-users mailing list -- [email protected]
To unsubscribe send an email to [email protected]

Reply via email to