Bonjour,

Maybe http://ceph.com/docs/giant/rados/troubleshooting/troubleshooting-mon/ can 
help ? Joao wrote that a few month ago and it covers a number of scenarios.

Cheers

On 24/10/2014 08:27, HURTEVENT VINCENT wrote:
> Hello,
> 
> I was running a multi mon (3) Ceph cluster and in a migration move, I 
> reinstall 2 of the 3 monitors nodes without deleting them properly into the 
> cluster.
> 
> So, there is only one monitor left which is stuck in probing phase and the 
> cluster is down.
> 
> As I can only connect to mon socket, I don't how if it's possible to add a 
> monitor, get and edit monmap.
> 
> This cluster is running Ceph version 0.67.1.
> 
> Is there a way to force my last monitor into a leader state or re build a 
> lost monitor to pass the probe and election phases ?
> 
> Thank you,
> _______________________________________________
> ceph-users mailing list
> ceph-users@lists.ceph.com
> http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com
> 

-- 
Loïc Dachary, Artisan Logiciel Libre