>From experience i can tell you that all mons need to use the same MTU between 
>eachother.

We moved from 1500 to 9000 a while ago and lost quorum while changing the MTU 
of the mons. Once all mons where at 9000, everything was fine again.
Cluster ran fine with 9000 on the OSD's + Clients and 1500 on MON's (but wht 
would you?)


----- Original Message -----
From: "Satish Patel" <satish....@gmail.com>
To: "ceph-users" <ceph-users@lists.ceph.com>
Sent: Thursday, August 16, 2018 5:53:07 PM
Subject: [ceph-users] Ceph-mon MTU question

Folks,

I am changing all my OSD node MTU to 9000 and just wonder does
ceph-mon node need MTU 9000 ? I know that are not going to deal with
high volume data but just curious does that impact functionality if
ceph-mon running on MTU 1500 and all OSD data node run on MTU 9000
(FYI: they all are on same LAN )