Dear All,

"micron" (recognised by Udunits) might be a good alternative to "um".


There is a typo in the last line of my message below -- question if whether to 
replace "1e6 km2" (not m2) with "Mm2",


regards,

Martin



________________________________
From: Juckes, Martin (STFC,RAL,RALSP)
Sent: 02 November 2018 08:55
To: Dave Allured - NOAA Affiliate; cf-metadata@cgd.ucar.edu
Subject: Re: [CF-metadata] Using units with a scale factor


Dear Karl, Dave,


thanks, those are good suggestions.


As Karl says, 1e3 km3 is not hm3 and can't be represented with prefixes 
(Udunits does accept


As a compromise, I suggest the following changes for the CMIP6 data request:
1e-3 kg --> g
1e6 J --> MJ

and retain 1e-6 m, 1e3 km3, 1e6 km2 with a comment. For the standard names we 
can just drop the scale factor as Karl suggests.


The reason these are in there is because people were not aware of the 
restriction. As I noted below, the restriction is also omitted from the 
conformance document and from the compliance checker. Units of this form are 
used when the community requests them, usually because that is the common 
practice within their community -- they probably exist in many NetCDF files 
outside CMIP.


I believe that the statement in the convention to the effect that scale_factor 
and add_offset attributes can be used instead is misleading. These factors can 
be used, but they only affect the internal storage of the data, they to not 
modify what the user sees -- I think the truth is that packing is the only 
application of these attributes. The units attribute needs to be consistent 
with what the user sees, and will not be affected by us of a scale factor. If 
the motivation for a particular choice of units is to avoid issues with 
numerical precision by adding an offset, this underlying problem can be dealt 
with using the offset attribute, but if the choice of units has different 
motivation these attributes don't help.


This leaves us with a problem that people want to store data in units of "1e3 
km3" and we cannot express this in CF (except by "Mm km2", which looks obscure 
to me). Is it reasonable to refuse units which are widely used in the 
community? I think it is worth taking some time to consider this, and I suggest 
that we allow this anomalous unit for CMIP6.


1e-6 m and 1e6 m2 we could use "um" and "Mm2", but I think the results would be 
unsatisfactory for the users. Although the unit micro-meter is in reasonably 
common use, the ascii representation "um" is a little obscure, and "Mm" also 
looks obscure to me. I'm happy to take other views on these.


regards,

Martin

________________________________
From: CF-metadata <cf-metadata-boun...@cgd.ucar.edu> on behalf of Dave Allured 
- NOAA Affiliate <dave.allu...@noaa.gov>
Sent: 01 November 2018 20:43
To: cf-metadata@cgd.ucar.edu
Subject: Re: [CF-metadata] Using units with a scale factor

It sounds like consistency is more important than CF perfection in a particular 
use case.  In that case, I suggest continuing use of CMIP6 prescribed unit 
strings for CMIP6 purposes only, and let the CMIP6 community know of this 
inconsistency with CF 3.1.  This will probably be the least confusing for all 
concerned.  People and software that understand UDUNITS will understand those 
scaled unit strings without help from CF.

--Dave


On Thu, Nov 1, 2018 at 1:39 PM, Taylor, Karl E. 
<taylo...@llnl.gov<mailto:taylo...@llnl.gov>> wrote:
Hi again,

I think some groups may have already written CMIP6 fields with  the currently 
specified units that violate the CF standard, but I'd rather have all CMIP6 
datasets have comparable numeric values, so we shouldn't change the units 
themselves, just the units attribute, as suggested originally.  This is 
possible, as Martin already indicated with one exception:

1e3 km3 --> hm3

I think this may be incorrect.  Wouldn't 1e3 km3 be interpreted as 1e3 (km)^3  
If so, then
1e3 km3 = (10 km)^3

and there is no prefix equivalent to "10 km", so I think we're in a fix for 
this one variable.

Karl



On 11/1/18 11:03 AM, Dave Allured - NOAA Affiliate wrote:
Martin, thanks for a well stated summation of this problem.

My opinion is there are good reasons for prohibiting numeric scale and offset 
in the units string, as indicated in section 3.1.  (Decimal prefixes are fine, 
as always.)  Therefore I agree with Karl's #1 and #3, keep the prohibition and 
do not change 3.1.

The CMIP6 data request itself is a problem because it actually violates CF 3.1. 
 Best remedy would be to get CMIP6 authority to agree to alternate units that 
do not use numeric scale factors.  I would modify Karl's #2 like this:

2)  Replace the scaled units in the CMIP6 data request with unscaled units and 
equivalent decimal prefix (e.g., replace  "1e6 J" with "MJ").  However, if the 
result is deemed not user friendly in some way, then decide on some user 
friendly unscaled units, e.g. "J", and consumers will need to re-scale data 
later, for some purposes.

Does anyone know why CMIP6 requested units in violation of CF 3.1?

--Dave


On Thu, Nov 1, 2018 at 10:58 AM, Taylor, Karl E. 
<taylo...@llnl.gov<mailto:taylo...@llnl.gov>> wrote:
Hi Martin,

I think the main point of the relevant paragraph in section 3.1, which reads

"The Udunits syntax that allows scale factors and offsets to be applied to a 
unit is not supported by this standard. The application of any scale factors or 
offsets to data should be indicated by the scale_factor and add_offset 
attributes. Use of these attributes for data packing, which is their most 
important application, is discussed in detail in Section 8.1, "Packed 
Data"<http://cfconventions.org/Data/cf-conventions/cf-conventions-1.7/cf-conventions.html#packed-data>."

is that if you want to pack the data, the proper way to do that is through 
scale_factor and add_offset, not through the scale and offset options allowed 
by udunits in the units attribute. In general I find the "scale_factor" and 
"add_offset" attributes much easier to interpret than the scale and offset 
udunits options.    I would therefore:

1) continue to forbid (or strongly discourage?) use of offset and scale in the 
units attribute (and modify the conformance document to be consistent with 
this).

2)  replace the scaled units in the CMIP6 data request with units that might be 
less user friendly, but include equivalent prefix (e.g., replace  "1e6 J" with 
"MJ")

3)  replace in the standard names table all non-conforming units with 
conforming units.  I don't think the new units need to be identical to the old 
(e.g., I would replace "1e-3 kg m-2" with "kg m-2", not "g m-2").

Regarding this last point, note that the so-called "Canonical units" in the 
standard names table are there to provide guidance on what the quantity 
represents (e.g., W m-2 indicates the quantity is a flux density, not a flux).  
CF does not recommend a particular unit among all equivalent (e.g., "kg" might 
appear in the canonical units, but "g" would be just as acceptable).

Do others have opinions about this?

best regards,
Karl


On 10/29/18 7:45 AM, Martin Juckes - UKRI STFC wrote:

Hello Karl, Alison,

As part of a separate discussion on 'months since' and 'years since' in time 
units<http://mailman.cgd.ucar.edu/pipermail/cf-metadata/2018/020648.html><http://mailman.cgd.ucar.edu/pipermail/cf-metadata/2018/020648.html>,
 Klaus pointed out the use of numerical scale factors in units strings, 
although allowed by Udunits, is prohibited by the CF convention in section 3.1. 
I'm raising this here because there are 3 standard names which make use of such 
scale factors in their canonical units, and a number of CMIP6 variables. The CF 
conformance document diverges from the standard and allows any string which is 
accepted by Udunits, and hence accepts such factors. The CF checker implements 
the version according to the conformance document, as does the cf-python code 
(and hence checks on the CMIP6 variables using cf-python didn't detect this 
problem).


The CF standard names are:

integral_wrt_depth_of_product_of_sea_water_density_and_salinity  : 1e-3 kg m-2

ocean_salt_x_transport, ocean_salt_y_transport: 1e-3 kg s-1


In the CMIP6 data request, we have:

1.e6 J m-1 s-1 for atmospheric energy transport (intuadse, intvadse);

1e-3 kg m-2 for integral wrt depth of density and salinity (somint);

1e-6 m s-1 for saturated hydraulic conductivity;

1e3 km3 for sea ice volumes (sivoln, sivols);

1e6 km2 for sea ice areas (siarean, siareas, siextentn, siextents);


Should we stick to the statement in the standards document ... and bring the 
conformance document etc into line, or could the standards document be 
interpreted more loosely?


These scale factors could be replaced by prefixes, but I think there is some 
loss of legibility in some cases:

1e-3 kg --> g

1e6 J --> MJ

1e-6 m --> um

1e3 km3 --> hm3

1e6 km2 --> Mm2


(here "um" is a micrometer, "hm" a hectometer and "Mm" a megameter).


regards,

Martin
_______________________________________________
CF-metadata mailing list
CF-metadata@cgd.ucar.edu
http://mailman.cgd.ucar.edu/mailman/listinfo/cf-metadata

Reply via email to