Tassos Chatzithomaoglou wrote: > Is the following error something to worry? Can this SSRAM memory be replaced?
Be sure to: 1. clear *all* config on the box which references the linecard (I use a spare chassis and "clear start") 2. Disable the periodic diags that run by default 3. Run the diag *immediately* after a linecard reboot I've seen various of the GOLD diags fail if there is *any* config on the box, certainly any referencing the linecard. I've also seen that particular diag fail if *any* other diag has run on the linecard since the last reboot, including the periodic "non-destructive" ones. _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/