We had a fire in a building where we stored a significant quantity of gear and are attempting to determine whether any of the gear in the vicinity can be trusted (and dealing with the insurance
adjustor).

Stuff sprayed with water or in dense smoke (everything on the floor of the fire) is thrown out of course.

I've got some switches which were 1 floor downstairs from the fire. They were in moderate smoke. They are dry, although the building was very humid (3 inches of water on floor). Most of them smell
smoky.

My worst judgement call is a pair of ASA5580-40's in the original packaging 1 floor down from the fire. They were inside a plastic bag inside a box on a pallet. The box is dry. Some condensation was noticed inside the plastic bag when it was opened up.

From my standpoint I don't want to trust any of this gear in production. Of course, the insurance
adjustor sees gear that appears undamaged and is now completely dry.

Anyone have experience running gear that was subjected to smoke, and possibly some
condensation?  Did it result in abnormal outages in the future?

Darrell Root
ciscotraining at mac.com

_______________________________________________
cisco-nsp mailing list  [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/

Reply via email to