You can't use reload at to meet your needs?

Jared Mauch

On Jun 24, 2009, at 8:25 AM, David Freedman <david.freed...@uk.clara.net> wrote:

Am trying to reload a low end IOS device (c800 in this case) without
displaying a confirmation prompt.

My issue is that the platform needing to issue the command can not "see"
the VTY output so could not be expected to respond to a confirmation
prompt, looked in vain for some kind of "/noconfirm" flag but didn't
find one...

Does not appear to be possible with SNMP (even though it accepts the
snmp-server shutdown command).

My current solution is to use an EEM applet called manually with a
single action of "reload" , unfortunately this only applies to 800
images with EEM (I would guess ADV images only)

Anybody come up with a better solution?

TIA

Dave.