•The switch supports hot swapping of the fan module. You can remove and replace the module without interrupting normal switch operation.
•When replacing the fan module, complete the replacement procedure within 2 minutes to avoid overheating the switch. •Make sure that all fan module captive screws are tightened before moving the switch. http://www.cisco.com/en/US/docs/switches/lan/catalyst3750e_3560e/hardware/install/notes/1757101.html#wp40415 HTH, Andrew On Apr 2, 2010, at 7:51 AM, Justin M. Streiner wrote: > Quick question for the peanut gallery. I have a Cat3560E-12D with a fan > module that's failing. A review of the various docs and data sheets on CCO > says that the fan modules are field replaceable, but not if they are > hot-swappable. In other words, do I have to plan for an outage to replace > the fan, assuming I would replace the old module immediately? > > jms > _______________________________________________ > cisco-nsp mailing list [email protected] > https://puck.nether.net/mailman/listinfo/cisco-nsp > archive at http://puck.nether.net/pipermail/cisco-nsp/ > _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/