> -----Original Message-----
> Sent: Tuesday, July 06, 2010 5:51 AM
> To: cisco-nsp@puck.nether.net; sunny.ie...@esprit.com
> Subject: [c-nsp] snmp config in PIX
> 
> 
> Dear all,
> 
> I am trying to set snmp agent in my PIX 506E FW(192.168.1.1). I am not good
> in PIX FW. The following is my configuration PIX506# sh snmp-server no
> snmp-server location no snmp-server contact snmp-server community
> mosnmpcommunity no snmp-server enable traps
> 
> After command, I can ping the snmp manager from my PIX506, but I still
> cannot get anything from my snmp manager(192.168.1.110) which is in the
> same network.
> I have also set in switches, and my snmp manager can see the switches.
> 
> Could anyone help me on this?
> 

I'm not quite sure if you're trying to poll or trap.  Either way, the PIX 6.x 
only support v1 SNMP and most polling or trapping software is going to default 
to v2c.  Try changing and see if it helps.  

snmp-server host inside x.x.x.x poll
snmp-server community notsoverypublic

-ryan

_______________________________________________
cisco-nsp mailing list  cisco-nsp@puck.nether.net
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/

Reply via email to