All,

We have three E1 voice circuits on a 2821 - two from the same provider on on E1 0/0/0 and E1 0/0/1, and a third from a different provider on a E1 0/1/0 - a separate VIC.

After fixing a broken fan on the router, the third E1 is experiencing slip seconds. The other two are clean, and I suspect this is due to the router being configure to use the clock from E1 0/0/0. There is no loss of service, however I'm keen to sort out this problem as it might affect service in the future.

How can I resolve the problem? Is it possible to use a different clock for each VIC?

Regards,


Peter

_______________________________________________
cisco-nsp mailing list  cisco-nsp@puck.nether.net
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/

Reply via email to