Hi, I have a puzzler.

I have two Cisco 7206VXr routers one with a G1 and the other with a 400 
processor.  
Between them terminated on a gig interface on each side is an ILEC provided 
metro E connection that’s pretty vanilla using VLANs to address different 
connections.

I have a /30 set up on a common VLAN between the two with the BGP peer set up 
on that /30.
    After 3 minutes, my session will reset I’m assuming do to lack of 
keepalives / problems with MTU.  Lots of googling as pointed me at various MTU 
mismatch situations but I’m not sure what I’m doing wrong possibly assuming 
something is set “in an interesting way” between the sites on the ILEC network.

On each interface I have the following

int gig x/x
mtu 1522

Assuming 1500 for standard Ethernet and 22 for the VLAN tags.
I also have the following set in global mode
ip tcp path-mtu-discovery

On both VXR devices code 12.4-25C is being run.

    I would appreciate any pointers to investigate.  What have I missed?


Thanks
Scott



_______________________________________________
cisco-nsp mailing list  cisco-nsp@puck.nether.net
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/

Reply via email to