On Tue, 2011-09-20 at 14:12 +0100, Jon Marshall wrote: > My confusion is when i read on here that when the 67xx modules are > running in CFC mode they send a portion of the packet (depending on > compact/truncated mode) across the 32Gbps bus to the supervisor for a > forwarding decision to be made. But if they don't have connectors to > the 32Gbps bus then how do they access it ?
They do have DBus connectors. Even the WS-X6708-10G-3C, even though the diagram doesn't show it. http://www.cisco.com/en/US/prod/collateral/switches/ps5718/ps708/prod_white_paper0900aecd80673385.html#wp9000639 > As a further question, assuming they do send lookups across the shared > bus then having classic linecards using the same bus could have a > direct impact on the performance of the 67xx modules ? AFAIK it will not impact the performance of traffic staying on fabric-enabled cards. (I'm not aware of any changes the Sup2T might introduce here.) -- Peter _______________________________________________ cisco-nsp mailing list cisco-nsp@puck.nether.net https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/