Hi Claes, Did you open a TAC case to track this issue? Regards, Waris
-----Original Message----- From: [email protected] [mailto:[email protected]] On Behalf Of Claes Jansson Sent: Thursday, August 30, 2012 8:10 AM To: [email protected] Subject: [c-nsp] ME3600X arp inspection issue Hi All, we seem to have discovered an issue with ME3600X and arp inspection. It seems to be affecting traffic flowing through the box. The test setup is like this... An "access switch" is connected at gi0/24, with a management interface on vlan2 (tagged). ! ME3600X ! me360x-universalk9-mz.152-4.S.bin ! License Level: AdvancedMetroIPAccess ! ! Will break ARP on vlan2! ! if removed everything works as expected ! ip arp inspection vlan 10 ! ip route 0.0.0.0 0.0.0.0 10.0.16.1 ! int te0/1 description UPLINK switchport mode trunk ! int gi0/24 description ACCESS_Switch switchport mode trunk ! interface Vlan2 ip address 10.0.16.166 255.255.255.0 no ip route-cache end ! ! ME3400 Access switch ! ip route 0.0.0.0 0.0.0.0 10.0.16.1 ! interface Vlan2 ip address 10.0.16.222 255.255.255.0 no ip route-cache ! A core switch / default gateway is connected to the ME3600X at te0/1. IP 10.0.16.1. If we on the ME3600X enable arp inspection on *ANY* vlan it will block arp traffic on vlan2. The only workaround we have found is to disable "ip arp inspection" on all vlans. Setting "ip arp inspection trust" on *all* interfaces does not solve the problem. ME3600X-test#sh ip arp inspection Source Mac Validation : Disabled Destination Mac Validation : Disabled IP Address Validation : Disabled Vlan Configuration Operation ACL Match Static ACL ---- ------------- --------- --------- ---------- 1 Disabled Inactive 2 Disabled Inactive 10 Enabled Active What does work with "ip arp inspection" enabled is this. ### ME3600X -- can ping default gateway 10.0.16.1 ME3600X -- can ping access-switch 10.0.16.200 ME3400 -- can ping ME3600 switch 10.0.16.166 ME3400 -- cannot ping core switch 10.0.16.1 (arp record listed as <incomplete>) Core switch -- cannot ping ME3400 switch 10.0.16.200 (although a correct arp-record is visible in the core switch) Core switch -- can ping ME3600X Also, we have another switch in production running "me360x-universalk9-mz.151-2.EY.bin, MetroIPAccess" that does not seem to be affected by this problem. I'm quite interested to hear if anyone else has come across this? //Claes _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/ _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/