Hello all and thanks in advance for the help on this topic. I have a 6500e that I want to power a few AP1250s using Enhanced Poe.
According to a lot of documentation, I should be able to get more then 16.8Watts from my PoE WS-X6148E-GE-45AT ge-tx blade (which says it can support upto 30Watts). My issue is that I am yet able to get more then the 16.8Watts on the line. I am running advipservicesk 122-33.SXJ which is newer then the minimal SXH2, do I need to be running adventerprise? Thanks again for any insight on this, db _______________________________________________ cisco-nsp mailing list cisco-nsp@puck.nether.net https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/