Thus spake Leigh Harrison (lharri...@convergencegroup.co.uk) on Fri, Mar 23, 
2012 at 12:48:06PM +0000:
> Hello all,
> 
> We have run into an issue on a 3750 switch where it has run out of spanning 
> tree instances.
> 
> Is this a limitation of PVST or is it a limitation of the switch?  I can't 
> seem to find good clarity anywhere.  I have some 6509's and nexus 7k's and 
> I'm wondering if they're going to suffer from the same fate...

It's a limitation of the switch.  I think in the data sheets for each
product you will find the number of supported instances.  The number of
instances is significantly higher for cat6k and n7k.

Also just take a look to see if you can get away with MST depending on your 
topology and expectations.

Dale
_______________________________________________
cisco-nsp mailing list  cisco-nsp@puck.nether.net
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/

Reply via email to