On Dec 16, 2013, at 4:34 PM, Nick Hilliard <[email protected]> wrote: > On 16/12/2013 21:31, Nick Hilliard wrote: >> first thing you want to do is set "load-interval 30" on both sides of the >> link, then wait a couple of minutes, then re-read the interface counters. > > err, got confused by Load-Interval #2 on the N3064 side. n/m. > > No idea which one is correct. The 7600 is known to have interesting > interpretations on how much traffic is flowing through its interfaces. > Actually on the 7600, you might want to increase the load-interval to > something larger than 30 seconds, because from what I remember this > platform only reads from line cards every several seconds, which means that > at a 30 second load interval, you'll end up with stepping problems causing > incorrect readings.
You can adjust this time with the “service counters” setting. - Jared _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/