Agreed. But even after a reboot, the chassis is still not allowing this 6708 card to come up because it complains about insufficient cooling.

This is pretty annoying as their documentation shows that the 7604 is compatible with this card but now we're starting to wonder if that's truly the case.

Jose

On 3/21/2014 9:42 AM, Phil Mayers wrote:
On 21/03/14 12:15, Lobo wrote:
Even though the cards are not completely compatible for totals # of
routes (3C vs 3CXL) the system should default to the lowest card but I
would think that it would still power up the card and let it function
normally.

No; the PFC/DFCs must all match. The other PFC/DFC need to be *downgraded* to non-XL mode, and that need a chassis reboot.
_______________________________________________
cisco-nsp mailing list  cisco-nsp@puck.nether.net
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/

_______________________________________________
cisco-nsp mailing list  cisco-nsp@puck.nether.net
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/

Reply via email to