I am bringing up a new link. This is on CWDM fiber with a supposedly 80km optic. Path is about 20 miles. I'm getting the following warning messages:

*Apr 29 2015 22:29:09.851 PST: %SFF8472-3-THRESHOLD_VIOLATION: Te0/3: Rx power low warning; Operating value: -16.4 dBm, Threshold value: -15.8 dBm.

The link is working fine without issue but I want to know what I'm looking at and wether it's worthwhile to do something about it?

Also in my show inventory for this I get:

NAME: "TenGigabitEthernet0/3", DESCR: "10GBASE-ER/EW"
PID: scrambled gobblydegook VID: scrambled crap , SN: INEAC0060007


The 'pid' and 'vid' values are all high bit chars undecipherable. Lastly, Im including the detail output in case any of these numbers make sense:

sh int te0/3 transceiver
ITU Channel not available (Wavelength not available),
Transceiver is internally calibrated.
If device is externally calibrated, only calibrated values are printed.
++ : high alarm, +  : high warning, -  : low warning, -- : low alarm.
NA or N/A: not applicable, Tx: transmit, Rx: receive.
mA: milliamperes, dBm: decibels (milliwatts).

                                           Optical   Optical
           Temperature  Voltage  Current   Tx Power  Rx Power
Port       (Celsius)    (Volts)  (mA)      (dBm)     (dBm)
---------  -----------  -------  --------  --------  --------
Te0/3        34.1       0.00      91.5       2.4     -16.4 -

sh int te0/3 transceiver detail

ITU Channel not available (Wavelength not available),
Transceiver is internally calibrated.
mA: milliamperes, dBm: decibels (milliwatts), NA or N/A: not applicable.
++ : high alarm, +  : high warning, -  : low warning, -- : low alarm.
A2D readouts (if they differ), are reported in parentheses.
The threshold values are calibrated.

                              High Alarm  High Warn  Low Warn   Low Alarm
           Temperature        Threshold   Threshold  Threshold Threshold
Port       (Celsius)          (Celsius)   (Celsius)  (Celsius) (Celsius)
---------  -----------------  ----------  ---------  --------- ---------
Te0/3        34.1                   74.0       70.0        0.0 -4.0

                              High Alarm  High Warn  Low Warn   Low Alarm
           Voltage            Threshold   Threshold  Threshold Threshold
Port       (Volts)            (Volts)     (Volts)    (Volts) (Volts)
---------  -----------------  ----------  ---------  --------- ---------
Te0/3        0.00                    N/A        N/A N/A        N/A

                              High Alarm  High Warn  Low Warn   Low Alarm
           Current            Threshold   Threshold  Threshold Threshold
Port       (milliamperes)     (mA)        (mA)       (mA)       (mA)
---------  -----------------  ----------  ---------  --------- ---------
Te0/3        91.5                    N/A        N/A N/A        N/A

           Optical            High Alarm  High Warn  Low Warn   Low Alarm
           Transmit Power     Threshold   Threshold  Threshold Threshold
Port       (dBm)              (dBm)       (dBm)      (dBm) (dBm)
---------  -----------------  ----------  ---------  --------- ---------
Te0/3         2.4                    6.9        3.9       -4.7 -7.7

           Optical            High Alarm  High Warn  Low Warn   Low Alarm
           Receive Power      Threshold   Threshold  Threshold Threshold
Port       (dBm)              (dBm)       (dBm)      (dBm) (dBm)
---------  -----------------  ----------  ---------  --------- ---------
Te0/3       -16.4         -          1.9       -1.0      -15.8 -18.8


Thanks.

_______________________________________________
cisco-nsp mailing list  cisco-nsp@puck.nether.net
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/

Reply via email to