Does it affect both Te ports at EXACTLY the same time? Or does one go down then a few seconds alter the other? If it's both at the same time, that smells a bit like an ASIC issue, as Adam said they share an ASIC for the TenG ports.
When you say this has happened on 5 switches, all 5 were ME3600-X's? Has it ever happened on more than one switch at the same time, two neighbouring switches for example have had all their TenG interface cease to function at the same time? Do you have out of band access to these PoPs? When you talk about getting TAC via WebEx and rebooting the switches I assume you do, is there anything else on the switch that isn't working? I.e all the 1G ports (or however your customers are connected) are working? BGP sessions up etc? Do any of these PoPs where you have had the issue have low enough traffic you could switch to a 1G link between them to trial for a while? Adam pointed out the RPs could be too busy to service the BFD requests, is the CPU high when the issue occurs? Are you able to mirror the ports (or SPAN) at one of the PoPs on the 10G ports, to see if any traffic is actually coming over from the neighbouring PoP, or being sent from the local switch? You said the switches seem to fail randomly, can you increase your NMS polling (since this sounds like a bug being triggered) to correlate the interface shutdowns to something like a spike in traffic, spike in latency between PoPs, IGP/BGP update/topology change coming through, LDP/RSVP update coming through? Cheers, James. _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/