Eehehe, yeah forgot about that one 6724 module which has the single fabric connection.

On 1/15/2016 6:10 PM, Pete Templin wrote:
Almost. 6724s (SFP or GE) will work in slots 1-8; they only use one fabric connection.

On 1/14/2016 5:18 PM, Paul wrote:
You are correct with the sup720, the 67xx line cards are only supported in slots 9-13.

On 1/13/2016 6:58 AM, Alireza Soltanian wrote:
Hi everybody

We are planning for installing Cisco 6513. Based on my researches, if we install SUP-2T on this Chassis we will have 80Gbps Fabric Switch capacity (Half-duplex) for each slot. But if we use SUP-720 then we will have 20Gbps
Fabric Switch capacity for Slots#1-6 and 40Gbps for slots#9-13.



--
GloboTech Communications
Phone: 1-514-907-0050 x 215
Toll Free: 1-(888)-GTCOMM1
Fax: 1-(514)-907-0750
p...@gtcomm.net
http://www.gtcomm.net

_______________________________________________
cisco-nsp mailing list  cisco-nsp@puck.nether.net
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/

Reply via email to