> On A-B link, where A=>B works but A<=B does not, A will go down and A
> will assert RFI or remote fault indicator on the line. B will receive
> this, and go down as well.
You're right as usual. I actually happened to see a 1000baseLX port in dispute
a few years ago, so you made me dig through old emails and tickets.
It was a 6500 facing a 3750, and it was because MSTP BPDUs where incorrectly
tagged, probably due to CSCta17209, we fixed upgrading the 3750.
Probably UDLD wouldn't have helped either.
Thanks,
Bergonz
--
Ing. Michele Bergonzoni - Laboratori Guglielmo Marconi S.p.a.
Phone:+39-051-6781926 e-mail: [email protected]
alt.advanced.networks.design.configure.operate
_______________________________________________
cisco-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/