Folks, I want to enable sFlow on Cisco nexus 9300 switch on 40G interface (GEM) module. but getting following error.
(config)# sflow data-source interface e2/5 In order to enable sFlow sampling on North star front panel port(Ethernet2/5), please either carve both span and sflow tcam regions with non-zero sizes using the commands 'hardware access-list tcam region span <size>' 'hardware access-list tcam region sflow <size>' or remove both span and sflow tcam regions and carve a span-sflow tcam region with a non-zero size using the commands When i am doing following, got error that means i don't have space in my tcam table so what is the best approve here? (config)# hardware access-list tcam region sflow 256 ERROR: Aggregate TCAM region configuration exceeded the available Ingress TCAM slices. Please re-configure. _______________________________________________ cisco-nsp mailing list cisco-nsp@puck.nether.net https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/