Hi Curtis,
Looks like we are on the same boat. We have similar experience with
traffic stepping down from F3e 100G ports to 10G F2e, and also in
parallel from F2e 10G to F2e 1G. Current TAC case opened for about 2
months for now, I had two troubleshooting sessions with different TAC
engineers and all I received after that were either out-of-office
notifications or promises to respond to the EoD|EoW which didn't happen
as of yet.
In our case the behavior of the issue is inconsistent: only particular
traffic is getting dropped and only on the certain path. Incoming and
outgoing ports are both in port-channels, no physical errors on the
ports, only VOQ drops. Tried to re-shake port-channels with shut/no shut
links one by one with no result. Some time ago segregated 10G ports to
different port groups and it helped for some time but the problem
re-appeared eventually. We are still on 6.2.12 and the outcome of
previous case a year ago was "upgrade and reboot" but we didn't go for
it partially because of the critical role of these switches and
partially because of lack of confidence in the platform and final
result. Fortunately, we found a workaround to reroute traffic to
different path. Now it's coming to the same 10G egress ports from
another 100G port-channel although 100G are on the same linecards as
that were dropping packets.
Any advice would be appreciated.
Kind regards,
Andrey Kostin
Curtis Piehler писал 2019-12-14 11:17:
I am hoping some of you Cisco Nexus veterans out there could shed some
light on this issue or provide some insight if this has been
encountered
before.
Has anyone had egress VQ Congestion issues on the Nexus 7k using F2e
line
cards causing input discards? There has been intentional influx of
traffic
over the past few months to these units (Primarily VoIP traffic) IE:
SBCs
and such. These SBCs are mostly 1G interfaces with a 10G uplink to the
core router. At some point of traffic shift the switch interfaces
facing
the SBC accrue egress VQ congestion and input discards start dropping
packets into the switches from the core router uplinks.
We have opened a Cisco TAC ticket and they go through the whole thing
about
the Nexus design and dropping packets on ingress if the destination
port is
congestion, etc... and I get all that. They also say going from a 10G
uplink to a 1G downlink is not appropriate however those downstream
devices
are not capable of 10G. They amount of traffic influx isn't that much
(your talking 20-30M max of VoIP). We have removed Cisco FabricPath
from
all VDCs and even upgraded our code from 6.2.16 to 6.2.20a on the
SUP-2E
supervisors.
I understand the N7K-F248XP-23E/25E have 288KB/Port and 256KB/SOC and I
would think these would be more than sufficient. I know the
F3248XP-23/25
have 295KB/Port 512KB/SOC however I can't see the need to drop 7x the
amount for line cards that should be able to handle this traffic?
We have recently taken the approach of moving the 1G SBCs down to a
N5596
VPC stack linked via 20G port-channel (per 5596) from the parent 7ks as
I
understand the 5596 have different egress queue structures and maybe
more
suited to handle this type of application?.
Any insight would be appreciated.
Thanks
_______________________________________________
cisco-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/
_______________________________________________
cisco-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/