I am having a rough time getting my home lab up and running, and would love 
to get some reccomendations on what to try next from the group. I feel like 
I have tried everything, but obviously I haven't, because it isn't working. 
Anyone care to help out?

CSU/DSU#1
TXD=solid green light
RXD=flashing green light
RTS=solid green light
CTS=solid green light
DCD=flashing green light
DTR=solid green light
OOS=flashing red light
LOS=flashing red light
ERR=flashing red light
TST=nothing

CSU/DSU#2
DSR=nothing
RTS=nothing
CTS=nothing
DCD=solid green light
TXD=nothing
RXD=solid green light
TST=nothing
NIS=nothing

  CSU/DSU#1 is set for internal clocking and #2 is set for external 
clocking. These are both set for synchronous 56k. The pinout noted in both 
instruction booklets shows pins 1 and 2 are transmit and pins 7 and 8 are 
receive and 3-6 are not used. I have 1 crossed to 8 and 2 crossed to 7. ( I 
also tried crossing 1 to 7 and 2 to 8 got the same thing).
CSU/DSU#1 is an ADC Kentrox D-serv 56, and CSU/DSU#2 is a 56K ROUTERmate 
made by Cray Communications.
  If I turn off #2 the flashing lights stop flashing and go dark, and the 
LOS goes to a solid red light.

  I have a 2501 connected to CSU/DSU#1 and a 2502 connected to CSU/DSU#2

  I just can't figure out what I am doing wrong anyone have any suggestions? 
I would be more than happy to give information I am not sure what else would 
be pertinent. Thank you in advance.
>>>Brian
________________________________________________________________________
Get Your Private, Free E-mail from MSN Hotmail at http://www.hotmail.com

___________________________________
UPDATED Posting Guidelines: http://www.groupstudy.com/list/guide.html
FAQ, list archives, and subscription info: http://www.groupstudy.com
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

Reply via email to