Breif example... Your local T1 ciruit to your carrier is Up Up but.. when
you do a  "sh frame-relay pvc" your DLCI shows INACTIVE. Hence why the ISDN
backup interface command does not take effect since the interface is still
up.. even though your frame-relay is not working. This can be caused to
certain instability within the cloud.. and not to your local CO's
frame-switch... LMI's will exchange every 10 sec from your router to the
Frame-Switch and provide a Full PVC status every 60 sec.

HTH,
Sal