Hi everybody

I have a Compaq server with 2 NC3121 cards. According with the docs, the
card supports Fast Etherchannel
static configuration (ON).
I couldn't find a procedure to set up Fast Etherchannel for the network card
so I did what I thought it was better.

I selected the following :
Teaming control =Load balancing
Load balancing options:
-----------------------------------
[x]Switch assisted load balancing
[ ]Transmit load balancing
-----------------------------------
[x ]Balance with MAC addresses
[ ]Balance with IP addresses
-----------------------------------

On the switch side I set up the following:

interface Port-channel
 no ip address
 flowcontrol send off
!
interface FastEthernet0/1
 no ip address
 channel-group 1 mode on
!
interface FastEthernet0/2
 no ip address
 channel-group 1 mode on

Everything looks fine, the redundancy works but how can I see if it works ?
I mean the load balancing.
I don't know the SNMP OID to monitor that interface. Judging by the blinking
lights it works only on one interface.
I made the tests selecting different classes of IPs (10 mod 2 and 10 mod 5)
for transmission on the server side
I set up the switch on source balancing. Not very sure that both MAC aren't
in the same class (MAC) mod 2.
The 'show int' command shows me load only on the first interface of the
channel.
The 'debug etherchanel' shows that the switch senses the disconnecting of
the interfaces (if I test this).

Any clue ?
Thank you
Chris




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=72601&t=72601
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]