url

do a no shut on serial intf
clock dce say 64000
then
sh controllers ser x 

Look at the       DCD=up  DSR=up  DTR=up  RTS=up  CTS=up

you have a working cable, interface 2x

http://www.cisco.com/univercd/cc/td/doc/product/software/ios122/122cgcr/fint
er_r/irfshoap.htm#1019003

http://www.cisco.com/en/US/tech/tk713/tk507/technologies_configuration_examp
le09186a0080094504.shtml

LET OP DE ONDERSTE REGEL DAN IS IE UP!

spicey#show interfaces serial 1
Serial1 is up, line protocol is up 
  Hardware is HD64570
  Internet address is 5.0.2.2/24
  MTU 1500 bytes, BW 1544 Kbit, DLY 20000 usec, 
     reliability 255/255, txload 1/255, rxload 1/255
  Encapsulation PPP, loopback not set
  Keepalive set (10 sec)
  LCP Open
  Open: IPCP
  Last input 00:00:01, output 00:00:01, output hang never
  Last clearing of "show interface" counters 00:09:27
  Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 0
  Queueing strategy: weighted fair
  Output queue: 0/1000/64/0 (size/max total/threshold/drops) 
     Conversations  0/1/256 (active/max active/max total)
     Reserved Conversations 0/0 (allocated/max allocated)
  5 minute input rate 0 bits/sec, 0 packets/sec
  5 minute output rate 0 bits/sec, 0 packets/sec
     130 packets input, 3392 bytes, 0 no buffer
     Received 0 broadcasts, 0 runts, 0 giants, 0 throttles
     0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort
     129 packets output, 3378 bytes, 0 underruns
     0 output errors, 0 collisions, 0 interface resets
     0 output buffer failures, 0 output buffers swapped out
     0 carrier transitions
     DCD=up  DSR=up  DTR=up  RTS=up  CTS=up


Martijn 

-----Oorspronkelijk bericht-----
Van: Jansen, M 
Verzonden: vrijdag 8 augustus 2003 12:36
Aan: 'LINSEN Jurgen (BMB)'; [EMAIL PROTECTED]
Onderwerp: RE: cisco back to back cable [7:71992]


In dutch, to keep things easy.

Denk dat je eerst even de  zaken moet proberen.

controle kabel
checken met commando sh controller serial, zie je een interface type staan,
dus die dce/dte

sh interface serial x
Router# show interfaces serial 
Serial 0 is up, line protocol is up 
   Hardware is MCI Serial 
   Internet address is 131.136.190.203, subnet mask is 255.255.255.0 
   MTU 1500 bytes, BW 1544 Kbit, DLY 20000 usec, rely 255/255, load 1/255 
   Encapsulation HDLC, loopback not set, keepalive set (10 sec) 
   Last input 0:00:07, output 0:00:00, output hang never 
   Output queue 0/40, 0 drops; input queue 0/75, 0 drops 
   Five minute input rate 0 bits/sec, 0 packets/sec 
   Five minute output rate 0 bits/sec, 0 packets/sec 
       16263 packets input, 1347238 bytes, 0 no buffer 
       Received 13983 broadcasts, 0 runts, 0 giants 
       2 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 2 abort 
1 carrier transitions 
22146 packets output, 2383680 bytes, 0 underruns 
0 output errors, 0 collisions, 2 interface resets, 0 restarts check onderaan
dte/dce/rts/cts signalen moeten werken

configuratie
standaard configuratie
de ene is dce  (moet commando clockrate bv 64000 bij)  
ander is dte geen clockrate



Martijn


-----Oorspronkelijk bericht-----
Van: LINSEN Jurgen (BMB) [mailto:[EMAIL PROTECTED]
Verzonden: vrijdag 8 augustus 2003 9:37
Aan: [EMAIL PROTECTED]
Onderwerp: RE: cisco back to back cable [7:71992]


Sure you're using a cross cable?

-----Original Message-----
From: KW S [mailto:[EMAIL PROTECTED] 
Sent: Monday, July 07, 2003 6:22 PM
To: [EMAIL PROTECTED]
Subject: cisco back to back cable [7:71992]


Dear All

I have a 2501 and 2505 and I am trying to set up a homelab..These 2
routers come with a cable which is a DB60(DTE) and the other end is a
DB60(DCE).This is wat that is label on the cable. Anyway, I try to
connect this cable to the serial interface of the 2 routers...and both
the routers are showing serial is down and line protocol is down.

I guess I have used the wrong cable...or maybe I have missed out
something.

Please comment..

Regards, kws
**** DISCLAIMER ****

"This e-mail and any attachment thereto may contain information which is
confidential and/or protected by intellectual property rights and are
intended for the sole use of the recipient(s) named above.
Any use of the information contained herein (including, but not limited to,
total or partial reproduction, communication or distribution in any form) by
other persons than the designated recipient(s) is prohibited.
If you have received this e-mail in error, please notify the sender either
by telephone or by e-mail and delete the material from any computer".

Thank you for your cooperation.

For further information about Proximus mobile phone services please see our
website at http://www.proximus.be or refer to any Proximus agent.
**Please support GroupStudy by purchasing from the GroupStudy Store:
http://shop.groupstudy.com
FAQ, list archives, and subscription info:
http://www.groupstudy.com/list/cisco.html




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=73714&t=73714
--------------------------------------------------
**Please support GroupStudy by purchasing from the GroupStudy Store:
http://shop.groupstudy.com
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html

Reply via email to