Hello there

This what I know FECNs and BECNs are traffic notifications used by a
Switch in this case Frame Relay switch..to notify end nodes i.e routers.
Routers will only reduce the rate of traffic transmission but it won't
stop...But if the router is configured for Frame Relay trffic-shapening
the FECN or BECN counters will reduce or controlled thus stop
increasing....in short router has to be Frame Relay traffic-shapening
configured if the FECN has to reducing its counters......Hope that
helps....

Thank you

Ollie
AT&T Common Backbone
866-397-7309 Opt 1


-----Original Message-----
From: Md Nazri [mailto:[EMAIL PROTECTED]
Sent: Tuesday, September 02, 2003 3:39 AM
To: [EMAIL PROTECTED]
Subject: in FECN [7:74642]


hi guys,

this is the output of my sh frame-relay pvc

DLCI = 171, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE =
Serial0/0.171

  input pkts 1435560       output pkts 9358712      in bytes 370699089
  out bytes 1069864391     dropped pkts 0           in pkts dropped 0
  out pkts dropped 0                out bytes dropped 0
  in FECN pkts 7738        in BECN pkts 56          out FECN pkts 0
  out BECN pkts 0          in DE pkts 0             out DE pkts 0
  out bcast pkts 193438    out bcast bytes 12380032
  5 minute input rate 20000 bits/sec, 7 packets/sec
  5 minute output rate 13000 bits/sec, 12 packets/sec
  pvc create time 1w6d, last time pvc status changed 4d00h

what will happen if 'in FECN' is increasing..how do router adapt to
it..?


thanks
**Please support GroupStudy by purchasing from the GroupStudy Store:
http://shop.groupstudy.com
FAQ, list archives, and subscription info:
http://www.groupstudy.com/list/cisco.html




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=74665&t=74642
--------------------------------------------------
**Please support GroupStudy by purchasing from the GroupStudy Store:
http://shop.groupstudy.com
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html

Reply via email to