Has anyone encountered the problems below.  This problem is on a Cisco 2505
router with serial interface debugging turned on.  I checked the keepalive
values on each connected interface and they match??



Sep 11 16:38:17 UTC: Serial0: HDLC myseq 842909, mineseen 842908, yourseen
354617, line up 
Sep 11 16:38:27 UTC: HD(0): Reset from 0x303C174

Sep 11 16:38:27 UTC: Serial0: HDLC myseq 842910, mineseen 842908, yourseen
354617, line up 
Sep 11 16:38:37 UTC: HD(0): Reset from 0x303C174

Sep 11 16:38:37 UTC: Serial: HDLC myseq 842911, mineseen 842908, yourseen
354617, line down 
Sep 11 16:38:37 UTC: %LINEPROTO-5-UPDOWN: Line protocol on Interface
Serial0, changed state to down

Sep 11 16:38:47 UTC: Serial0: HDLC myseq 842912, mineseen 842912, yourseen
354621, line up 
Sep 11 16:38:47 UTC: %LINEPROTO-5-UPDOWN: Line protocol on Interface
Serial0, changed state to up

Sep 11 16:38:57 UTC: Serial0: HDLC myseq 842913, mineseen 842913, yourseen
354622, line up 
Sep 11 16:39:07 UTC: Serial0: HDLC myseq 842914, mineseen 842914, yourseen
354623, line up 


Thanks,

Stan Rossetti


Russia Services Group
Email:  [EMAIL PROTECTED]
Phone:  (256) 544-5031
Beeper:  544-1183 pin # 0112

 <<...>> 



**NOTE: New CCNA/CCDA List has been formed. For more information go to
http://www.groupstudy.com/list/Associates.html
_________________________________
UPDATED Posting Guidelines: http://www.groupstudy.com/list/guide.html
FAQ, list archives, and subscription info: http://www.groupstudy.com
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

Reply via email to