Has anyone encountered the problems below. This problem is on a Cisco 2505
router with serial interface debugging turned on. I checked the keepalive
values on each connected interface and they match??
Sep 11 16:38:17 UTC: Serial0: HDLC myseq 842909, mineseen 842908, yourseen
354617, line up
Sep 11 16:38:27 UTC: HD(0): Reset from 0x303C174
Sep 11 16:38:27 UTC: Serial0: HDLC myseq 842910, mineseen 842908, yourseen
354617, line up
Sep 11 16:38:37 UTC: HD(0): Reset from 0x303C174
Sep 11 16:38:37 UTC: Serial: HDLC myseq 842911, mineseen 842908, yourseen
354617, line down
Sep 11 16:38:37 UTC: %LINEPROTO-5-UPDOWN: Line protocol on Interface
Serial0, changed state to down
Sep 11 16:38:47 UTC: Serial0: HDLC myseq 842912, mineseen 842912, yourseen
354621, line up
Sep 11 16:38:47 UTC: %LINEPROTO-5-UPDOWN: Line protocol on Interface
Serial0, changed state to up
Sep 11 16:38:57 UTC: Serial0: HDLC myseq 842913, mineseen 842913, yourseen
354622, line up
Sep 11 16:39:07 UTC: Serial0: HDLC myseq 842914, mineseen 842914, yourseen
354623, line up
Thanks,
Stan Rossetti
Russia Services Group
Email: [EMAIL PROTECTED]
Phone: (256) 544-5031
Beeper: 544-1183 pin # 0112
<<...>>
**NOTE: New CCNA/CCDA List has been formed. For more information go to
http://www.groupstudy.com/list/Associates.html