Here is what I found and the site where I found it
 

       * The Active Monitor removes circulating frames from the ring. As a
       frame passes the Active Monitor, a special bit called a monitor
       count bit is set. If the monitor count bit is set, the Active
       Monitor assumes the original sender of the frame was unable to
       remove the frame from the ring. The Active Monitor purges this
       frame, and sends a Token Error Soft Error to the Ring Error Monitor.
 

http://www.landfield.com/faqs/LANs/token-ring-faq/

Jim

Leon Bass wrote:

I have been trying to track down a solution for this error, any suggestions are appreciated.

I have changed cables.
And in the process of scheduling to switch TokenRing cards.
I have pasted the interface with the erroe as it appears.

TokenRing0/0 is up, line protocol is up
  Hardware is IBM2222, address is 1110.12ae.1212 (bia 0180.69ae.1234)
  Internet address is 192.99.29.1/24
  MTU 4464 bytes, BW 16000 Kbit, DLY 630 usec,
     reliability 255/255, txload 1/255, rxload 1/255
  Encapsulation SNAP, loopback not set
  Keepalive set (10 sec)
  ARP type: SNAP, ARP Timeout 04:00:00
  Ring speed: 16 Mbps
  Duplex: half
  Mode: Classic token ring station
  Group Address: 0x00000000, Functional Address: 0x08000000
  Ethernet Transit OUI: 0x000000
  Last Ring Status 00:32:29 <Soft Error> (0x2000)
  Last input 00:00:00, output 00:00:00, output hang never
  Last clearing of "show interface" counters never
  Queueing strategy: fifo
  Output queue 0/40, 0 drops; input queue 0/75, 0 drops
  5 minute input rate 10000 bits/sec, 11 packets/sec
  5 minute output rate 2000 bits/sec, 3 packets/sec
     2968655 packets input, 416906220 bytes, 0 no buffer
     Received 0 broadcasts, 0 runts, 0 giants, 0 throttles
     256 input errors, 2 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort
 --More--
 