You can change the sampling time using the 'load-interval [interval]' 
command. That will give you anything from 30 seconds to 10 minutes in 30 
second increments.


>
>Is there a way to get the average utilization on an interface (serial) for 
>more than the default 5 minute period shown by show interfaces?  Perhaps if 
>there was a setting to increase the time period used, or a command that 
>would keep a running tally or even a way to record the utilization in the 
>syslog every so often.  Any ideas on how to do this without resorting to 
>using a third party application?
>
>Thanks.
>
_________________________________________________________________________
Get Your Private, Free E-mail from MSN Hotmail at http://www.hotmail.com.

Share information about yourself, create your own public profile at 
http://profiles.msn.com.

_________________________________
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html