when i dialed  a 3640 router ,i got the following error ,it seems that i got
connected ,but soon it cut off.( Async packet I/O debugging is on)
any help would be appreciated .

cisco#
01:08:41: %LINK-3-UPDOWN: Interface Async65, changed state to up
01:08:41: APPP65: Output packet, len = 29, header = FF 3 C0 21
00:4294967296:34359738368: APPP65: Input packet, len = 27, header = FF 3 C0
21
01:08:46: %LINK-5-CHANGED: Interface Async65, changed state to reset
01:08:51: %LINK-3-UPDOWN: Interface Async65, changed state to down

Current configuration:
!
version 12.0
service timestamps debug uptime
service timestamps log uptime
no service password-encryption
!
hostname cisco
!
!
username frank password 0 cisco
!
!
!
!
modem country microcom_hdms usa
ip subnet-zero
!
!
interface Serial1/0
 ip address 172.20.112.1 255.255.255.0
 no ip directed-broadcast
!
interface Serial1/1
 no ip address
 no ip directed-broadcast
 shutdown
!
interface Serial1/2
 no ip address
 no ip directed-broadcast
 shutdown
!
interface Serial1/3
 no ip address
 no ip directed-broadcast
 shutdown
!
interface Group-Async1
 ip unnumbered Serial1/0
 no ip directed-broadcast
 encapsulation ppp
 async default routing
 async mode interactive
 peer default ip address pool default
 ppp authentication chap
 group-range 65 72
!
ip local pool default 172.20.112.10 172.20.112.14
ip classless
no ip http server
!
!
!
line con 0
 transport input none
line 65 72
 autoselect during-login
 autoselect ppp
 login local
 modem InOut
 transport input all
line aux 0
line vty 0 4
 login
!
!
end



_________________________________
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

Reply via email to