Hi all,
I have one you may be able to help with. One of our guys came to me and I don't have
an instant answer to this.
A 2611 router with multiple bri's not using PPP Multi.
The dialer idle timeout is set to 1000000 in the dialer interface.
If the router drops and comes back up one of the channels will come back up with the
dialer idle timeout set back to 1000000 secs the others come back as 120 secs. This
is verified using the "show dialer" command. It requires dropping the bri and
restting the dialer idle timeout in the dialer map.
Looking forward to your input
Thanks
Teunis
Hobart, Tasmania
Australia
--
www.tasmail.com