I am having trouble on a 2621 with a WIC-DSU-T1.  The 2621 is connected to a
1600 with the same WIC via T1 point-to point.  When we move any substantial
amount of data accross the circuit we observe line code errors.  We observed
these by doing a show service-module on the 2621.
The 2621 is connected to the NIU through a jack and 180 foot 25 pair cable.
The 25 pair cable is terminated on both ends with 66 blocks.  The telco was
already out and tested with a TBird at the jack and of course they said it
tested fine.
Here is the interesting part - we also have a 3640 with a network module
that was having the same problem.  We used a service-module t1 lbo -15db and
it corrected the line code errors.  The same command did not correct the
problem on the 2621.
Does anybody have a clue?