The way we implement it is pretty easy...
Just run fibre from one building to another, and terminate it with SC
connectors. (I like them better than ST) in a fibre box. From there you just
need to run a patch MT-RJ --> SC from the Box to the core 6509. ( you will
have to purchase small MT-RJ to SC cables if you put the Fibre box in a rack
close to the 6509.
Good luck... Even if cost is a problem, remember that running fibre is a
good investment.
Gonzalo, CCNP
"Moahzam Durrani" <[EMAIL PROTECTED]> wrote in message
[EMAIL PROTECTED]">news:[EMAIL PROTECTED]...
> Were planning to connect a new building in our campus to our datacentre by
> fiber. the distance is way greater then 400 ft . The core switch is a
6509.
> Will I be using a MT-RJ to ST . Do i need anything else .. cost is a
> factor.
>
> Mo Durrani
> IS&T
> WYSE\EDS
> phone:408-473 1246
> [EMAIL PROTECTED]
> [EMAIL PROTECTED]
>
>
> _________________________________
> FAQ, list archives, and subscription info:
http://www.groupstudy.com/list/cisco.html
> Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]
>