Gladly, I think the frame error coincided with a line proto bounce
I think it may be environmental at site - maybe
Serial0/0 is up, line protocol is up
Hardware is PowerQUICC Serial
Description: 128k Frame Relay Service Y216077142N
MTU 1500 bytes, BW 1544 Kbit, DLY 20000 usec,
reliability 255/255, txload 1/255, rxload 6/255
Encapsulation FRAME-RELAY IETF, loopback not set
Keepalive set (10 sec)
LMI enq sent 5960, LMI stat recvd 5959, LMI upd recvd 0, DTE LMI up
LMI enq recvd 0, LMI stat sent 0, LMI upd sent 0
LMI DLCI 0 LMI type is ANSI Annex D frame relay DTE
Broadcast queue 0/64, broadcasts sent/dropped 28365/0, interface broadcasts 27328
Last input 00:00:00, output 00:00:00, output hang never
Last clearing of "show interface" counters 16:33:25
Queueing strategy: fifo
Output queue 0/40, 0 drops; input queue 0/75, 0 drops
5 minute input rate 42000 bits/sec, 20 packets/sec
5 minute output rate 11000 bits/sec, 17 packets/sec
307661 packets input, 75148222 bytes, 0 no buffer
Received 0 broadcasts, 0 runts, 0 giants, 0 throttles
1 input errors, 0 CRC, 1 frame, 0 overrun, 0 ignored, 0 abort
315493 packets output, 34616802 bytes, 0 underruns
0 output errors, 0 collisions, 1 interface resets
0 output buffer failures, 0 output buffers swapped out
0 carrier transitions
DCD=up DSR=up DTR=up RTS=up CTS=up
>>> John Neiberger <[EMAIL PROTECTED]> 03/14 11:09 am >>>
Could we also see a copy of "show interfaces"? I didn't see anything
obviously wrong with what you already posted, except that the logs are out
of order. Well, I'm not sure what those LMI status timeouts mean. It's not
dropping keepalives, though. Hmmm... Yes, please post some more interface
info.
And do you have any other information? Have you replaced the CSU/DSU? Have
you replaced both cables attached to it? Have you tried a different port on
the router, or a different router?
John
> Hi All
>
> I've a FR site 32/64Kbit that flaps intermittantly
> The carrier has check it & says nothing is wrong, cable has been replaced
>
> detail below:
>
> router#sh fr pvc
>
> PVC Statistics for interface Serial0/0 (Frame Relay DTE)
>
> Active Inactive Deleted Static
> Local 1 0 0 0
> Switched 0 0 0 0
> Unused 0 0 0 0
>
> DLCI = 16, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE =
Serial0/0.16
>
> input pkts 251505 output pkts 254458 in bytes 60629859
> out bytes 29044923 dropped pkts 794 in FECN pkts 0
> in BECN pkts 0 out FECN pkts 0 out BECN pkts 0
> in DE pkts 10933 out DE pkts 0
> out bcast pkts 26559 out bcast bytes 2862020
> Shaping adapts to BECN
> pvc create time 15:31:26, last time pvc status changed 02:16:23
>
> router#sh fr lmi
>
> LMI Statistics for interface Serial0/0 (Frame Relay DTE) LMI TYPE = ANSI
> Invalid Unnumbered info 0 Invalid Prot Disc 0
> Invalid dummy Call Ref 0 Invalid Msg Type 0
> Invalid Status Message 0 Invalid Lock Shift 0
> Invalid Information ID 0 Invalid Report IE Len 0
> Invalid Report Request 0 Invalid Keep IE Len 0
> Num Status Enq. Sent 5588 Num Status msgs Rcvd 5588
> Num Update Status Rcvd 0 Num Status Timeouts 49
>
> Mar 14 10:22:01: Serial0/0(in): Status, myseq 162
> Mar 14 10:22:01: RT IE 1, length 1, type 1
> Mar 14 10:22:01: KA IE 3, length 2, yourseq 195, myseq 162
> Mar 14 10:22:11: Serial0/0(out): StEnq, myseq 163, yourseen 195, DTE up
> Mar 14 10:22:11: datagramstart = 0x1B759D4, datagramsize = 14
> Mar 14 10:22:11: FR encap = 0x00010308
> Mar 14 10:22:11: 00 75 95 01 01 01 03 02 A3 C3
>
> Mar 14 10:16:51: Serial0/0(in): Status, myseq 131
> Mar 14 10:16:51: RT IE 1, length 1, type 0
> Mar 14 10:16:51: KA IE 3, length 2, yourseq 164, myseq 131
> Mar 14 10:16:51: PVC IE 0x7 , length 0x3 , dlci 16, status 0x2
> Mar 14 10:17:01: Serial0/0(out): StEnq, myseq 132, yourseen 164, DTE up
> Mar 14 10:17:01: datagramstart = 0x1B75254, datagramsize = 14
> Mar 14 10:17:01: FR encap = 0x00010308
> Mar 14 10:17:01: 00 75 95 01 01 01 03 02 84 A4
>
> Mar 14 10:19:51: Serial0/0(in): Status, myseq 149
> Mar 14 10:19:51: RT IE 1, length 1, type 0
> Mar 14 10:19:51: KA IE 3, length 2, yourseq 182, myseq 149
> Mar 14 10:19:51: PVC IE 0x7 , length 0x3 , dlci 16, status 0x2
> Mar 14 10:20:01: Serial0/0(out): StEnq, myseq 150, yourseen 182, DTE up
> Mar 14 10:20:01: datagramstart = 0x1B759D4, datagramsize = 14
> Mar 14 10:20:01: FR encap = 0x00010308
> Mar 14 10:20:01: 00 75 95 01 01 01 03 02 96 B6
>
> Mar 14 10:20:51: Serial0/0(in): Status, myseq 155
> Mar 14 10:20:51: RT IE 1, length 1, type 0
> Mar 14 10:20:51: KA IE 3, length 2, yourseq 188, myseq 155
> Mar 14 10:20:51: PVC IE 0x7 , length 0x3 , dlci 16, status 0x2
> Mar 14 10:21:01: Serial0/0(out): StEnq, myseq 156, yourseen 188, DTE up
> Mar 14 10:21:01: datagramstart = 0x1B74AD4, datagramsize = 14
> Mar 14 10:21:01: FR encap = 0x00010308
> Mar 14 10:21:01: 00 75 95 01 01 01 03 02 9C BC
>
> Mar 14 10:21:51: Serial0/0(in): Status, myseq 161
> Mar 14 10:21:51: RT IE 1, length 1, type 0
> Mar 14 10:21:51: KA IE 3, length 2, yourseq 194, myseq 161
> Mar 14 10:21:51: PVC IE 0x7 , length 0x3 , dlci 16, status 0x2
> Mar 14 10:22:01: Serial0/0(out): StEnq, myseq 162, yourseen 194, DTE up
> Mar 14 10:22:01: datagramstart = 0x1B74D54, datagramsize = 14
> Mar 14 10:22:01: FR encap = 0x00010308
> Mar 14 10:22:01: 00 75 95 01 01 01 03 02 A2 C2
>
>
> Any help appreciated
>
> Thankyou
>
> David
>
> _________________________________
> FAQ, list archives, and subscription info:
http://www.groupstudy.com/list/cisco.html
> Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]
_______________________________________________________
Send a cool gift with your E-Card
http://www.bluemountain.com/giftcenter/
_________________________________
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]