Probably line no error, try the following equation to calculate the right line no. that you are using. The below is only for 3600 series. Interface no.=(32 x slot no.) + unit no. +1. Hope htis help Vincent ""Niraj Palikhey"" Hi, > I am trying to setup a 3640 router with 3 async interfaces for reverse > telnet but it's not working. > On the 3640, I consoled in and created 8 loopback interfaces 1-8 with ip's > starting at 1.1.1.1......8.8.8.8. I have ip host R1 2001 1.1.1.1 thru ip > host R8 2008 8.8.8.8 configured. > I also have under line 33 48 > #transport input all > #flowcontrol hardware > > Presently, I only have 2 other routers connected to the 3640. When I type R1 > on the 3640, I get a connection refused error msg. Same for R2. > I unplugged the octal connector and connected it to the second port on the > 1st async interface. Same problem > I configured the other lines and plugged the octal connector to those ports. > Same problem. > Is there something that I am missing or doing wrong. > One thing that I am trying to understand is that Do I have to actually > Telnet to the 3640 and then do a reverse telnet instead of consoling into it > and trying to get to the other router's console?? > Please advise. > Thank you, > Kind regards, > [EMAIL PROTECTED] > _________________________________________________________________ > Get your FREE download of MSN Explorer at http://explorer.msn.com Message Posted at: http://www.groupstudy.com/form/read.php?f=7&i=230&t=230 -------------------------------------------------- FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]