Had nothing better to do than sell my easy to configure & predictably slow
2511 for a 2621 with an NM-16 async module.  I am @ a loss as to logic
involved with the async line numbering.  With the 2500 Access-Server, line 1
is 2001 (2000 being Telnet protocol).  My 2621 has the NM-16 in slot 1 (as
seen in the below output):

Firewall#sh diag
Slot 1:
        Async port adapter, 16 ports

The given formula is this: interface # = (16 x slot #) + unit # +1

 (16x slot # 1) + 1 (physical connection 1) + 1= gives me 18  The router
starts the count @ 33 as the first useable line #.  So- my range of 16
useable
lines is 33 thru 48.  My question is:

What gives ???

What's the logic here ???

Thanks !!!
Phil




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=10532&t=10532
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]