The Network never supplies clock on a T1. Clocking is provoided
by one of the End Points.

Since you can sync up to yourself when you loop the remote end it
sounds like you may have a timing mismatch between you csu/dsu's.

You may want to check to see what timeslots each CSU is using. If they
don't match up you can get timing slips like you are getting.

You also need to set one CSU/DSU for internal timing and the other
for line/network timing.


Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=21986&t=21955
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]