Thanks Tim Hickman for his correct response. The 4006 has 3 power supplies, needs two to run and I had the third turned off hence the faulty status.
time for eine bier!!! Dave MADMAN wrote: > > Just working with a customer whose Cat4K had "lost" all it's line > cards. Anyway got it back up and working but the customer noticed the > the status of the sup card was faulty, running 6.1.2 catOS. I logged > into my cat4k in the lab running 6.1.3 and noticed the same thing. Must > be cosmetic, anyone else see/seen this???? > > Mod Slot Ports Module-Type Model Sub Status > --- ---- ----- ------------------------- ------------------- --- > -------- > 1 1 2 1000BaseX Supervisor WS-X4013 no faulty > 2 2 34 Router Switch Card WS-X4232-L3 no ok > 3 3 48 Inline Power Module WS-X4148-RJ45V no ok > 4 4 1 Voice Gateway WS-X4604-GWY no ok > > > -- > David Madland > Sr. Network Engineer > CCIE# 2016 > Qwest Communications Int. Inc. > [EMAIL PROTECTED] > 612-664-3367 > > "Emotion should reflect reason not guide it" -- David Madland Sr. Network Engineer CCIE# 2016 Qwest Communications Int. Inc. [EMAIL PROTECTED] 612-664-3367 "Emotion should reflect reason not guide it" Message Posted at: http://www.groupstudy.com/form/read.php?f=7&i=22080&t=22067 -------------------------------------------------- FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]