Etherchannel make the link 1 logical connection.  Therefore, one STP
interface.  If one link fails it becomes a single connection, so you are
still up.

-----Original Message-----
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]]On Behalf Of
DAGENHARDT Frank
Sent: Thursday, November 08, 2001 1:04 PM
To: [EMAIL PROTECTED]
Subject: Switch Question [7:25704]


I have dual Gigabit trunk links connecting my two Catalyst 4003 switches. My
STP type is IEEE. If I configure those two links as Etherchannel will one of
those links still be blocked by STP? Or will the Etherchannel trunk be
viewed by STP as only one link. Is there any disadvantage to doing this
instead of letting it be blocked by STP for redundancy.

Thanks

Frank




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=25709&t=25704
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]