Maybe this will explain it..Just because a serial int is UP/UP, it doesn't
necessarily mean that data is able to be xfered.  The serial int could be
connected to a CSU/DSU which might give the int the correct control signal
states to make the serial int appear to be up (example would be that the
remote CSU/DSU is broken but carrier signal is up on local int).  In this
case, since it's frame relay, the 2nd up would not occur unless LMI
keepalives were occuring.  What cisco is saying is UP/UP is just the int
status.  Doesn't mean that data is being xfered. The most popular way to
know that an interface is in use is to watch in/out stats (via sh int). 
Clear counters is another usefull cmd.