Anil,

I'm sorry, my explaination wasn't very good.  The answer can't be B since
you have no information saying data is being sent and received.  The answer
A does fit since a frame relay connection is active if int status is UP/UP.

As far as the 2nd part, AFAIK not every encap uses keepalives.  Frame Relay
is somewhat special in that an UP/UP status really means that data COULD be
xfer'ed.  The case of the broken remote CSU/DSU does not fit this scenarios
since keepalives would not be received.  The question seems geared toward
trying to trick the engineer into thinking that data is being xfered vs.
could be.  Many encap use keepalives.  A few are F/R, ATM, PPP and HDLC (PPP
uses an echo).  Not sure if all do (probably not).  Hope that helps.




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=27949&t=27930
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

Reply via email to