The answer is A or B... if you have just one pvc coming in from the 
switch, and inverse-arp running
you don't have to do anything on the spoke.   B would work fine if 
inverse-arp is working.
A would take care of everything and leave nothing to chance.  (all 
considering one pvc coming into the spoke)

Rajesh Kumar wrote:

>Hi all,
>
>Can somebody clarify me the following :
>
>1.  In a Hub-Spoke configuration of FR network, what is the appropriate
>configuration on the spoke side when it is a
>
>        (a)   Physical Interface :         FR map statements /
>Interface-dlci
>
>        (b)   Point-Point interface :        I am pretty sure it is
>Interface-dlci config.
>
>        (c)    Multipoint interface  :    FR map /  Interface-dlci
>                ( I know it doesn't mean much by making a spoke to be a
>multipoint
>                    interface, but lets keep for argument sake..)
>
>
>Thanks,
>Rajesh




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=36314&t=36293
--------------------------------------------------