This might sound really strange, but, if you are using a normal D25way
connector (v.24) see if it works when pin 13 isn't connected.

I once had all sorts of problems with IBM controllers both 5394 / 5494 and
3174 / 3274, after hours of troubleshooting finally ran through a breakout
box and found that some of the controllers didn't like pin 13. Don't know
why, but as soon as I removed it they all worked fine.

I wasn't able to nail it down to a particular device / sw / fw combination
but it worked for me. I suggest doing it with a breakout box before you
start breaking pins with snip nosed pliars though ! :)

Jon.

""Ashok C Braganza""  wrote in message
[EMAIL PROTECTED]">news:[EMAIL PROTECTED]...
> Can anyone help me in configuring AS/400 Controller 5394
>
> Here is my configuration
> interface Serial1/0
>  no ip address
>  encapsulation sdlc
>  no keepalive
>  nrzi-encoding
>  clockrate 9600
>  sdlc role prim-xid-poll
>  sdlc vmac 4030.0000.0000
>  sdlc T1 20000
>  sdlc address 01
>  sdlc xid 01 05F00001
>  sdlc partner 8800.0000.0040 01
>  sdlc dlsw default
>
>
> I have two controllers 5394 & 5494. I have no problem with 5494.
> Any idea?
> Thanks in advance,
>
> Ashok Braganza




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=37812&t=37759
--------------------------------------------------