Try testing head to head. That is the only true way to test a circuit. A loop will only verify connectivity.
Vijendra Jaiswal wrote: >Hello All , > >Secenario: >Channelized E1 card on 3600 series router connected to Mux at Telco end . > >Observations: >When the E1 is completely looped the Telco gets the loop very fine on the >BERT meter .No slips , No errors > >Problem: >When any of the individual timeslots on the E1 is looped then the Telco gets >slip error on the BERT meter .Due to this any of the 64K circuits configured >on any of the timeslots gets at least 2 ping timeouts out of every 1000 ping >packets when any of the timeslot is looped from the Cisco or Telco end. > >Solution tried: >1) Changed the clock source from internal/external on the channelized E1 >card but the problem remains the same. >2) Changed 02 cards at TELCO end , problem remains the same . > >Cisco WAN champions pls let me have your feedback on the above problem so as >to resolve it. > >Thanks in advance. >Vijendra. Message Posted at: http://www.groupstudy.com/form/read.php?f=7&i=38436&t=38371 -------------------------------------------------- FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]